XSN series intelligent counterCan be equipped with various photoelectric switches, proximity switches, grating rulers, incremental rotary encoders and other pulse output sensors for counting purposes; Measure displacement and length; Measure the angle. Single phase pulse or biphasic orthogonal pulse input, with a maximum counting frequency of 10kHz. The counting ratio can be set within a wide range of 0.0001 to 45.000. 2-point preset output. Two output modes, with the ability to set delay recovery and automatic reset functions. It can achieve range alarm and automatic quantitative (fixed length) control. Welcome to consult with all users.
Basic specifications
project |
specification |
|
power supply voltage |
ACpower supply |
100~240 V AC 50/60 Hz |
AC/DCpower supply |
10~24V AC 50/60 Hz;10~24V DC |
|
power consumption |
ACpower supply |
7 VAbelow |
AC/DCpower supply |
AC:6 VAfollowing;DC:5Wbelow |
|
Allowable voltage variation range |
The voltage of the power supply90%~110% |
|
insulation resistance |
≥100MΩ(500V DC MEGABenchmark) |
|
insulation strength |
2000V AC (Test conditions:50/60Hz,1Minutes) |
|
anti-interference |
IEC61000-4-2(Electrostatic discharge))Grade III IEC61000-4-4(Electric Fast Transient Pulse Group), Level III IEC61000-4-5(Surge), Level III |
|
Protection level |
IP65(Product front panel protection)(GB/T42-2008) |
|
runtime environment |
ambient temperature |
-10~55℃(Save:-25~65℃) |
ambient humidity |
35~85 %R•HNo condensation |
|
Installation location |
Indoor, height<2000m |
|
XSNSeries intelligent counterInput specifications
project |
specification |
||
Input signal type |
Pulse input |
||
Type of input signal |
Single-phase pulse (20mAAbove) |
1 |
Applicable toNPNThePNPTheOCGate voltage pulse,2thread system4~20mApulseTTLPulse, etc. signal amplitude1V~30VUniversal. |
Biphasic orthogonal pulse |
2 |
Applicable toNPNThePNPTheOCGate voltage pulse, signal amplitude3V~24V |
|
10HzThe following single-phase pulse input |
D |
Suitable for low-speed counting to prevent input signal jitter. |
|
Maximum counting frequency |
10kHz |
||
display range |
5Position display instrument |
-19999~45000The decimal point position can be set. |
|
7Position display instrument |
-9999999~9999999The decimal point position can be set. |
||
★ The input specifications are determined according to the needs, based on the model number4Partial representation.
■ Optional specifications
project |
specification |
||||
Preset output |
T1~T2 |
1~2Point relay preset output,250V AC/3A, resistive load |
|||
|
Analog output (Limited)5Position display instrument |
A1 |
current output(4~20)mAThe(0~10)mAThe(0~20)mA |
opto-isolation Resolution:1/3000 Load capacity:600Ω |
||
A2 |
voltage output(1~5)VThe(0~5)V |
||||
A3 |
voltage output(0~10)V |
||||
A4 |
Voltage output(-5V~+5V) |
||||
A5 |
Voltage output(-10V~+10V) |
||||
external control |
K1 |
zero clearing |
Signal width greater than20msPassive switch or voltage control When controlled by a passive switch, closure is effective and disconnection is ineffective During voltage control,4VThe above is valid,1VThe following is invalid, load current>4mA |
||
K2 |
Reset, add/reduce |
||||
K3 |
Reset, add/Reduce and lock |
||||
communication interface |
S1 |
RS232Interface,TC ASCIIagreement |
opto-isolation Speed:2400、4800、 9600The19200 bps Address:0~99 Response time:500μS(Measurement value) |
||
S2 |
RS485Interface,TC ASCIIagreement |
||||
M1 |
RS232Interface,Modbus-RTUagreement |
||||
M2 |
RS485Interface,Modbus-RTUagreement |
||||
external power supply |
B1 |
24V±5%,50mAbelow |
|||
B2 |
12V±5%,50mAbelow |
||||
B3 |
5V±5%,50mAbelow |
||||
Printing interface |
P |
Hardware clock |
|||
Counting ratio method |
C1 |
Single count ratio method |
|||
C2 |
Multiple Count Ratio Method (Limited)5Position display instrument) |
||||