- 이메일
- 전화
-
주소
Liushi Town, Yueqing City
Yueqing East Electric Co., Ltd
Liushi Town, Yueqing City
OneVM130-01-02SA roller type mechanical switch valveModel meaning:
VM is an SMC series mechanical valve, 1:100 series, 30: two position three-way double side inlet and outlet long push rod, 01: the connecting pipe diameter of the mechanical valve is G1/8,02S indicates that the button head of the mechanical valve is a one-way roller head, and the roller material is iron.
II Standard specifications:
Piping form: Side piping type
Using fluids: air and inert gas
Pressure range: 0.1-1.0Mpa
Environmental temperature and usage air temperature: -5 to 60 ° C (but not frozen)
Connection diameter: 1/8
III Product Features:
Small, equivalent to a miniature switch
You can choose the direction of piping, lateral piping type and bottom piping type
The lateral piping type can choose installation methods.
There are various types and colors of buttons available for multiple choices
Knowledge related to four mechanical valves:
1. Manual operability (button type, knob type, etc.) Mechanical valves are operated by hand.
When using mechanical tools such as cylinders or rollers, or hammers to operate, if the cargo causes damage to the actuator or valve body, do not exceed the maximum operating limit. Exceeding the action limit position may cause deformation, damage, and poor action of the actuator when operated with excessive force;
2. This series of machine control valves cannot be used as emergency shut-off valves.
In situations where this series is used, please be sure to take other measures that can ensure safety.
3. Cannot be used for pressure maintenance
The VM100 series and VM200 series are seat valve structures, and when the 2 (A) side is under high pressure, it will reverse flow, causing air leakage inside the valve. They cannot be used for pressure maintenance that includes vacuum.
When setting up a mechanical operated valve, do not exceed the action limit position for operation adjustment and installation
When operating beyond the limit position of the action, it will cause damage to the mechanical valve itself, damage to the device, and poor operation of the device.
5. Use fluids specifically for air and inert gases, and do not use corrosive gases or liquids.
When using vacuum pressure in the VM100 series, please supply vacuum pressure at the P port.
7. Cam and pressure plate angles for mechanical operation type actions. Do not exceed the maximum operating speed.
When used beyond the maximum value, the impact force of the cam and pressure plate on the operating mechanism can cause damage to the actuator and valve body.