환영 고객!

회원

도움말

Anhui Baolong Pump Valve Co., Ltd
주문 제조자

주요 제품:

instrumentb2b>제품

Anhui Baolong Pump Valve Co., Ltd

  • 이메일

    jsjn81@163.com

  • 전화

    13865489555

  • 주소

    Jingxian Development Zone, Xuancheng City, Anhui Province

지금 연락

FP polypropylene centrifugal pump

협상 가능업데이트05/25
모델
제조업체의 성격
생산자
제품 카테고리
원산지 Place of Origin

개요

FP polypropylene centrifugal pump

제품 정보


Product Introduction
1、 Introduction to Enhanced Polypropylene Centrifugal Pump: (Corrosion resistant Centrifugal Pump)
The FP type reinforced polypropylene centrifugal pump series products all use mechanical seals and (reinforced polypropylene) as the material of the pump. Among plastic pump products in the same series, it is characterized by light weight, small volume, and long service life. It is widely used in chemical, food, pharmaceutical, electroplating, papermaking, environmental protection, water treatment and other departments to transport corrosive liquids such as acids, alkalis, and salts. Among them, the 104 type adopts 220V voltage and can be used for household selection.
2、 Model Description:
3、 Performance parameters:

model

caliber

Flow rate m3/h

Head m

Suction distance

rotational speed

r/min

voltage

v

Motor power kw

Import

Export

FP20-15-60 (106)

20

15

1

5

3

2900

380

0.12

FP20-20-90(105)

20

20

3

6

3

380

0.37

FP32-25-100(104)

32

25

5

7

6

220

0.55

FP32-25-105(103)

32

25

6.3

8

6

380

0.75

FP32-25-110

32

25

8

14

6

380

1.1

FP40-32-125(102)

40

32

12.5

20

6

380

1.5

FP50-40-145

50

40

13

22

6

380

2.2

FP65-50-150(101)

65

50

25

25

6

380

4

50FP-22

50

40

13

22

6

380

2.2

65FP-25

65

50

20

25

6

380

4

80FP-28

80

65

50

28

4

380

5.5

80FP-32

80

65

50

32

4

380

7.5



4、 Structural diagram



1. Pump casing 2, impeller shaft assembly 3, mechanical seal 4, pump cover 5, motor


5、 Pump malfunction forms and troubleshooting methods


failure mode

cause

Troubleshooting

The pump cannot produce liquid

  1. Pump reversal
  2. Leakage in the inlet pipeline
  3. There is too little liquid stored in the pump chamber
  4. The suction distance is too high
  5. Bottom valve leakage
  6. Impeller obstructed and unable to rotate
  7. Change the motor wiring
  8. Eliminate air leakage
  9. Increase the storage capacity
  10. Lower the installation position of the pump
  11. Clean the bottom valve
  12. Clean the pump casing and impeller

Insufficient traffic

  1. The suction pipe diameter is too small
  2. Impeller channel blockage
  3. Head too high
  4. There is air leakage in the suction pipeline
  5. Damaged impeller
  6. Replace the liquid inlet
  7. Clean the impeller
  8. Turn up the outlet valve
  9. Eliminate air leakage
  10. Replace the impeller

Low head

  1. Too much traffic
  2. The speed is too low
  3. Turn down the outlet valve
  4. Restore rated speed

Low noise level

  1. There are debris inside the pump
  2. Friction between rotating parts and fixed parts
  3. Severe wear of the shaft
  4. Check and clean
  5. GAP
  6. Replace the pump shaft

Leakage of liquid

  1. Loose fixing screws of pump casing
  2. Severe wear of mechanical seal
  3. tighten the screws
  4. Replace the mechanical seal